Lightning arrester module for Blitzductor XT - Combined arrester for signal systems BXT ML2 B 180

BXT ML2 B 180 920211 4013364120570 EAN/GTIN DE 11890845 WEEE

Our best price
5,563.43₹ excl. VAT
10,536.30₹ (-47.2% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Lightning arrester module for Blitzductor XT BXT ML2 B 180 Rated voltage DC 180 ... 180V, maximum... more
Lightning arrester module for Blitzductor XT - Combined arrester for signal systems BXT ML2 B 180 – Dehn – 920211 – 4013364120570: Lightning arrester module for Blitzductor XT BXT ML2 B 180 Rated voltage DC 180 ... 180V, maximum continuous voltage AC 127V, maximum continuous voltage DC 180V, lightning impulse current (10/350 µs) 10kA, nominal discharge current (8/20) 20kA, nominal load current 1.2A , protection level wire/wire 650V, protection level wire/earth 550V, type of mounting on base element, connection 1 other, arrester monitoring, explosion-tested design, space-saving two-pole lightning current arrester module with LifeCheck and shield earthing for almost all applications. Can be used in conjunction with a downstream surge arrester -Type2P1 or combined arrester with a lower or the same voltage level. LifeCheck detects thermal or electrical overload conditions after which the arrester must be replaced. The display is contactless using DEHNrecord LC / SCM / MCM.
... more
Rated voltage DC 180V
Highest continuous voltage AC 127 V
Highest continuous voltage DC 180V
Lightning impulse current (10/350 µs) 10 kA
Nominal discharge current (8/20) 20 kA
Nominal load current 1.2 A
Protection level wire / core 650V
Protection level core / earth 550V
Mounting on base element
Connection 1 Screw terminal
SPD yes
With telecommunication contact no
Explosion-tested version yes
Separation option for signal circuit no
Number of conductors (without earth) 2
Earthing via DIN rail
Overall width 12 mm
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Lightning arrester module for Blitzductor XT - Combined arrester for signal systems BXT ML2 B 180"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.