Blitzductor XT combi arrester module - Combined arrester for signal systems BXT ML4 BE HF 5

Dehn - BXT ML4 BE HF 5 - Blitzductor XT combi arrester module - Combined arrester for signal systems BXT ML4 BE HF 5
Photo source: fig. possibly similar
Photo source: fig. possibly similar
BXT ML4 BE HF 5 920370 4013364109117 EAN/GTIN DE 11890845 WEEE

Our best price
13,334.65₹ excl. VAT
25,256.21₹ (-47.2% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Combination arrester module Blitzductor XT BXT ML4 BE HF 5 Rated voltage DC 5 ... 5V, maximum... more
Blitzductor XT combi arrester module - Combined arrester for signal systems BXT ML4 BE HF 5 – Dehn – 920370 – 4013364109117: Combination arrester module Blitzductor XT BXT ML4 BE HF 5 Rated voltage DC 5 ... 5V, maximum continuous voltage AC 4.2V, maximum continuous voltage DC 6V, lightning impulse current (10/350 µs) 10kA, nominal discharge current (8/20) 20kA, nominal load current 1A, protection level wire/wire 11V, protection level wire/earth 11V, limit frequency 100MHz, type of installation on base element, connection 1 other, arrester monitoring, explosion-tested design, space-saving combined arrester module with LifeCheck to protect 4 individual wires with a common reference potential as well as high-frequency transmissions without electrical isolation . LifeCheck detects thermal or electrical overload conditions after which the arrester must be replaced. The display is contactless using DEHNrecord LC / SCM / MCM.
... more
Rated voltage DC 5 V
Highest continuous voltage AC 4.2V
Highest continuous voltage DC 6V
Lightning impulse current (10/350 µs) 10 kA
Nominal discharge current (8/20) 20 kA
Nominal load current 1 A
Protection level wire / core 11 V
Protection level core / earth 11 V
Cut-off frequency 100 MHz
Mounting on base element
Connection 1 Screw terminal
SPD yes
With telecommunication contact no
Explosion-tested version yes
Separation option for signal circuit no
Number of conductors (without earth) 4
Earthing via DIN rail
Overall width 12 mm
IP protection) IP20

Rate item