Energy measurement sensor +ext. sensor - Energy management for bus system CEMU-01/03

CEMU-01/03 136476 4015081332588 EAN/GTIN DE 92318050 WEEE

Our best price
12,664.84₹ excl. VAT
20,220.70₹ (-37.37% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Energy measurement sensor +ext. Sensor CEMU-01/03 radio bus system, Powernet bus system, other... more
Energy measurement sensor +ext. sensor - Energy management for bus system CEMU-01/03 – Eaton – 136476 – 4015081332588: Energy measurement sensor +ext. Sensor CEMU-01/03 radio bus system, Powernet bus system, other xComfort bus systems, radio bidirectional, other design, connection type convertible, S0 pulse interface without, accuracy class 0, min. depth of the device box 26mm, the ''energy measurement sensor with external sensor'' is added used to record the solar energy converted in the PV inverter and then to transmit this to the room manager with ''energy management function'' for display. This type of device is used for larger outputs of 15 W-23 kW. Current, voltage, active power and electrical energy are determined. The external sensor of the energy measurement sensor is plugged into the electrical system via the output line, preferably at the feed point. The device is installed in the junction box or installation box. Device is not calibrated, therefore not suitable for billing purposes!
... more
Bus system KNX no
Bus system KNX radio no
Bus system radio bus yes
Bus system LON no
Bus system Powernet yes
Other bus systems xComfort
Radio bidirectional yes
Execution other
Connection changeable
Reactive power no
Approval according to PTB no
S0 pulse interface without
Tariff switching no
Min. depth of the device socket 26 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Energy measurement sensor +ext. sensor - Energy management for bus system CEMU-01/03"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.