Energy measurement sensor - Energy management for bus system CEMU-01/04

CEMU-01/04 136477 4015081332595 EAN/GTIN DE 92318050 WEEE

Our best price
8,905.46₹ excl. VAT
14,098.84₹ (-36.84% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Energy measurement sensor CEMU-01/04 radio bus system, Powernet bus system, other xComfort bus... more
Energy measurement sensor - Energy management for bus system CEMU-01/04 – Eaton – 136477 – 4015081332595: Energy measurement sensor CEMU-01/04 radio bus system, Powernet bus system, other xComfort bus systems, radio bidirectional, other design, direct connection, S0 pulse interface without, accuracy class 0, min. depth of the device socket 26mm, zEnergy measurement sensorz is used to To record solar energy converted by the inverter and then to transmit this to the room manager for display with the ''energy management function''. This type of device is used for outputs from 3-3680W. Current, voltage, active power and electrical energy are determined. The zenergy measurement sensorz is preferably connected to the electrical system at the feed-in point. The device is installed in the junction box or installation box. Device is not calibrated, therefore not suitable for billing purposes!
... more
Bus system KNX no
Bus system KNX radio no
Bus system radio bus yes
Bus system LON no
Bus system Powernet yes
Other bus systems xComfort
Radio bidirectional yes
Execution other
Connection directly
Reactive power no
Approval according to PTB no
S0 pulse interface without
Tariff switching no
Min. depth of the device socket 26 mm