Mains rectifier 24V 10A UPS Rufs.834 - System device clinic-installation 596800

Gira - 596800 - Mains rectifier 24V 10A UPS Rufs.834 - System device clinic-installation 596800
Photo source: fig. possibly similar
Photo source: fig. possibly similar
596800 4010337058922 EAN/GTIN DE 59229780 WEEE

Our best price
88,485.59₹ excl. VAT
132,721.44₹ (-33.33% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Mains rectifier 24V 10A USV Rufs.834 596800 Composition of basic element, power supply design,... more
Mains rectifier 24V 10A UPS Rufs.834 - System device clinic-installation 596800 – Gira – 4010337058922: Mains rectifier 24V 10A USV Rufs.834 596800 Composition of basic element, power supply design, type of power supply bus system, bus-capable 2-wire, power supply 24 V 10 A, uninterruptible Suitable for the Gira call system 834 Plus and the Gira call system 834. Features: Absolutely couples the output in the event of a power failure. Switches to battery power without interruption. Has automatic deep discharge protection of the battery. Automatic battery test. Temperature-controlled battery charging. Integrated ground fault monitoring. Notes: Fault and power failure messages: Suitable for use in accordance with DIN VDE 0834 Parts 1 and 2 Conformity with: IEC 60601-1 2 x MOPP, EN 55022 class B, EN 61000-3-2, -3, EN 61000-4-2 , -3, -4,-5, -6, -8, -11 (test level 3), EN 60950-1. Select the installation location so that the ventilation openings of the device remain free.
... more
Compilation Base element
Execution Power adapter
Type of power supply Bus system
Busable 2-wire

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Mains rectifier 24V 10A UPS Rufs.834 - System device clinic-installation 596800"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.