Ceiling spacer black, PA66GF15 BK 10 - Recessed installation box for luminaire SpotClipII 148-00098

SpotClipII 148-00098 148-00098 4031026439525 EAN/GTIN DE 92457933 WEEE

Our best price
438.71₹ excl. VAT

5-6 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Ceiling spacer sw, PA66GF15 BK 10 SpotClipII 148-00098 Suitable for HV lights, Suitable for LV... more
Ceiling spacer black, PA66GF15 BK 10 - Recessed installation box for luminaire SpotClipII 148-00098 – Hellermann Tyton – 148-00098 – 4031026439525: Ceiling spacer sw, PA66GF15 BK 10 SpotClipII 148-00098 Suitable for HV lights, Suitable for LV lights, Suitable for LED lights, Suitable for lamp power 35 ... 35W, Cavity ceiling application, Installation width 90mm, Installation depth 95mm, Installation length 107mm, Max Luminaire diameter 115mm, minimum ceiling thickness 8mm, material other, SpotClip-II was developed for larger recessed spotlights up to 95mm total height. Creates a safety distance between recessed spotlights, vapor barrier film and insulation material. 4 additional, flexible straps prevent contact between loose insulating material and the luminaire body, therefore ideally suited for the use of bulk and blow-in insulating materials. Remove a tab by breaking it out to accommodate the transformer or power cord. Provides greater stability through the improved design of the 4 support feet. Suitable for installation diameters of 62 - 90 mm. Tested according to EN 60598-1 and EN 60598-2-2. The SpotClip-II spacer has been developed for the secure installation of recessed spotlights in false ceilings. It can be easily inserted into the ceiling recesses and saves a considerable amount of time during installation. The shape allows a safe distance between the lamp and the insulating material and reduces the risk of overheating. SpotClip-II is suitable for both halogen and LED recessed lights.
... more
Suitable for HV luminaires yes
Suitable for low-voltage lights yes
Suitable for LED lights yes
Suitable for lamp power 35 W
Application Hollow ceiling
With operating room no
Installation width 90 mm
Depth 95 mm
Installation length 107 mm
Max. Luminous diameter 115 mm
Minimum ceiling thickness 8 mm
Material Plastic