Lightning Controller Rail 3-pin. with FS 255V - Combined arrester for power systems MCF38-NAR-TNC+FS

OBO - MCF38-NAR-TNC+FS - Lightning Controller Rail 3-pin. with FS 255V - Combined arrester for power systems MCF38-NAR-TNC+FS
Photo source: fig. possibly similar
Photo source: fig. possibly similar
MCF38-NAR-TNC+FS 5096973 4012196608812 EAN/GTIN DE 64419409 WEEE

26,623.85₹ excl. VAT
52,175.33₹ (-48.97% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Lightning Controller Rail 3-pin. m.FS 255V MCF38-NAR-TNC+FS TN network type, TN-C network type,... more
Lightning Controller Rail 3-pin. with FS 255V - Combined arrester for power systems MCF38-NAR-TNC+FS – OBO – 5096973 – 4012196608812: Lightning Controller Rail 3-pin. m.FS 255V MCF38-NAR-TNC+FS TN network type, TN-C network type, TN-CS network type, TN-S network type, TT network type, number of poles 3, lightning impulse current (10/350 µs) 12.5kA, maximum continuous voltage AC 255V , nominal voltage AC 230V, protection level 1.5kV, protection level LN 1.5kV, protection level N-PE 1.5kV, follow current extinguishing capacity 50kA, max. conductor cross-section solid (solid/stranded) 35mm², max. conductor cross-section flexible (finely stranded) 35mm², busbar mounting type , size other, remote signaling, optical signaling on the device, test class type 1 and 2, The MCF38-NAR combined arrester type 1+2 for lightning protection equipotential bonding according to VDE 0185-305 (IEC 62305) is suitable for use in the pre-counter area according to the VDEW guideline. The MCF38-NAR is used in buildings with lightning protection or overhead line feed in TN-C systems. It is installed on 40 mm busbars in the connection compartment on the mains side. The protection level of <=1.5 kV protects the end devices in the system. The lightning current discharge capacity is 38 kA (10/350) in total and 12.5 kA (10/350) per pole, follow current extinguishing up to 50 kA with a max. backup fuse up to 160 A gL/gG. The FS variant is also equipped with a potential-free changeover contact that enables remote signalling.
... more
Network shape TN yes
Mains form TN-C yes
Lightning impulse current (10/350 µs) 12.5 kA
Nominal discharge current (8/20) 20 kA
Highest continuous voltage AC 255V
Rated voltage AC 230V
Protection level 1.5 kV
Mounting Bus bar
Size other
Signaling on the device optical
IP protection) IP20