Lightning barrier 5V AC - Combined arrester for signal systems FLD 5

OBO - FLD 5 - Lightning barrier 5V AC - Combined arrester for signal systems FLD 5
Photo source: fig. possibly similar
Photo source: fig. possibly similar
FLD 5 5098600 4012195578369 EAN/GTIN DE 64419409 WEEE

6,562.45₹ excl. VAT
12,790.99₹ (-48.69% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Lightning barrier 5V AC FLD 5 Maximum continuous voltage AC 5V, maximum continuous voltage DC 8V,... more
Lightning barrier 5V AC - Combined arrester for signal systems FLD 5 – OBO – 5098600 – 4012195578369: Lightning barrier 5V AC FLD 5 Maximum continuous voltage AC 5V, maximum continuous voltage DC 8V, lightning impulse current (10/350 µs) 1.5kA, nominal discharge current (8/20) 5kA, nominal load current 1A, protection level wire/wire 15V, protection level wire/earth 600V, frequency 0MHz, cut-off frequency 0.18MHz, mounting type DIN rail TH35, connection 1 terminal, overvoltage protection for use in measurement, control and regulation technology - medium and fine protection - standard version for double-wire systems - two-stage protective circuit - with easy-to-install, screwless connection terminals - in the space-saving 17.5 -mm grid dimensions - with inductive decoupling in the longitudinal branch Application: Universal use on 35 mm DIN rails in any commercially available distributor housing.
... more
Highest continuous voltage AC 5 V
Highest continuous voltage DC 8 V
Lightning impulse current (10/350 µs) 1.5 kA
Nominal discharge current (8/20) 5 kA
Nominal load current 1 A
Protection level wire / core 15 V
Protection level core / earth 600V
Frequency 0 MHz
Cut-off frequency 1593 lm
Mounting DIN rail TH35
Connection 1 Clamp
With telecommunication contact no
Explosion-tested version no
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Lightning barrier 5V AC - Combined arrester for signal systems FLD 5"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.