Lightning barrier 110V AC - Combined arrester for signal systems FRD 110

OBO - FRD 110 - Lightning barrier 110V AC - Combined arrester for signal systems FRD 110
Photo source: fig. possibly similar
Photo source: fig. possibly similar
FRD 110 5098557 4012195578338 EAN/GTIN DE 64419409 WEEE

6,401.46₹ excl. VAT
12,476.71₹ (-48.69% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Lightning barrier 110V AC FRD 110 Maximum continuous voltage AC 86V, maximum continuous voltage... more
Lightning barrier 110V AC - Combined arrester for signal systems FRD 110 – OBO – 5098557 – 4012195578338: Lightning barrier 110V AC FRD 110 Maximum continuous voltage AC 86V, maximum continuous voltage DC 122V, lightning impulse current (10/350 µs) 1.5kA, nominal discharge current (8/20) 5kA, nominal load current 0.2A, protection level wire/wire 300V, protection level wire/earth 600V , frequency 0MHz, cut-off frequency 3.6MHz, mounting type DIN rail TH35, connection 1 terminal, overvoltage protection for use in measurement and control technology - medium and fine protection - standard version for double-wire systems - two-stage protective circuit - with easy-to-install, screwless connection terminals - in the space-saving 17 .5 mm pitch - with ohmic decoupling in the longitudinal branch Application: Universal use on 35 mm DIN rails in any commercially available distributor housing.
... more
Highest continuous voltage AC 86 V
Highest continuous voltage DC 122V
Lightning impulse current (10/350 µs) 1.5 kA
Nominal discharge current (8/20) 5 kA
Nominal load current 0.2 A
Protection level wire / core 300V
Protection level core / earth 600V
Frequency 0 MHz
Cut-off frequency 3,6 MHz
Mounting DIN rail TH35
Connection 1 Clamp
SPD no
With telecommunication contact no
Explosion-tested version no
IP protection) IP20