Control via MODBUS/TCP - Modular PLC CPU-module PLC-CPU-module ILC 191 ETH 2TX

ILC 191 ETH 2TX 2700976 4046356665520 EAN/GTIN DE 50738265 WEEE

Our best price
42,219.77₹ excl. VAT

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Control via MODBUS/TCP ILC 191 ETH 2TX supply voltage at AC 50 Hz 19.2 ... 30V, supply voltage at... more
Control via MODBUS/TCP - Modular PLC CPU-module PLC-CPU-module ILC 191 ETH 2TX – Phoenix – 2700976 – 4046356665520: Control via MODBUS/TCP ILC 191 ETH 2TX supply voltage at AC 50 Hz 19.2 ... 30V, supply voltage at AC 60 Hz 19.2 ... 30V, supply voltage at DC 19.2 ... 30V, voltage type of the supply voltage DC , Modular design, processing time (1K, binary instruction) 0.0013ms, number of HW interfaces Industrial Ethernet 2, number of interfaces PROFINET 0, number of HW interfaces serial RS-232 1, number of HW interfaces serial RS-422 0 , number of HW interfaces serial RS-485 0, number of HW interfaces parallel 0, number of HW interfaces wireless 0, number of HW interfaces other 1, number of analog outputs 0, number of analog inputs 0, number of digital inputs 8, number of digital outputs 4, supports protocol for INTERBUS, supports protocol for PROFINET IO, supports protocol for other bus systems, system component, memory type NVRAM, memory size 1024kByte, program memory extension possible, mounting rail internal assembly possible, SIL according to IEC 61508 without, width 80mm, height 120.4mm, depth 71.5mm, The Inline controller offers the possibility to communicate via PROFINET and Modbus/TCP. Programming is done with PC Worx Express or PC Worx (IEC 61131-3).
... more
Supply voltage at AC 50 Hz 19.2..30 V
Supply voltage at AC 60 Hz 19.2..30 V
Supply voltage at DC 19.2..30 V
Voltage type of the supply voltage DC
Execution modular
Processing time (1K, binary instruction) 0.0013 ms
Number of HW interfaces Industrial Ethernet 2
Number of digital inputs 8th
Number of digital outputs 4
With optical interface no
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS yes
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO yes
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Supports protocol for other bus systems yes
System component yes
Redundancy no
With display no
Memory Type NVRAM
Memory size 1024 kbytes
Program memory extension possible yes
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
SIL according to IEC 61508 without
Width 80 mm
Height 119.8 mm
Depth 71.5 mm

Rate item