Motor protection circuit-breaker 115A GV4P115N6

Schneider Electric - GV4P115N6 - Motor protection circuit-breaker 115A GV4P115N6
Photo source: fig. possibly similar
GV4P115N6 3606481310545 EAN/GTIN DE 33842582 WEEE

33,066.56₹ excl. VAT
58,680.84₹ (-43.65% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Motor protection switch 115A 3P 50kA GV4P115N6 overload release current setting 65 ... 115A,... more
Motor protection circuit-breaker 115A GV4P115N6 – Schneider Electric – 3606481310545: Motor protection switch 115A 3P 50kA GV4P115N6 overload release current setting 65 ... 115A, setting range of the instantaneous short-circuit release 1955 ... 1955A, with thermal protection, sensitive to phase failure, electronic release technology, rated operating voltage 0 ... 690V, rated continuous current Iu 115A, rated operational power at AC-3, 230 V 30kW, rated operational power at AC-3, 400 V 55kW, connection type main circuit screw connection, design of the actuating element rotary knob, device type complete device in the housing, number of poles 3, rated limiting short-circuit breaking current Icu at 400 V, AC 50kA, protection class (IP) IP40, height 155mm, width 81mm , depth 165mm, motor protection switch TeSys GV4 with thermal and magnetic tripping from 2A to 115A rated current load. These devices are easy to operate and set up, with a compact and ergonomic design and for the highest requirements of up to 50kA in the area of low-voltage switchgear. Equipped with a rotary drive for easy operation and the option of connecting cable lugs or ribbons.
... more
Overload release Current setting 65..115 A
With thermal protection yes
Phase failure sensitive yes
Release system electronic
Rated operating voltage 690V
Rated continuous current Iu 115 A
Rated operating power at AC-3, 230V 30 kW
Rated operating power at AC-3, 400V 55 kW
Connection type main circuit Screw
Execution of the actuating element Knob
Device construction Complete device in the housing
With integrated auxiliary switch no
With integrated undervoltage release no
Number of poles 3
IP protection) IP40
Height 155 mm
Width 81 mm
Depth 165 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Motor protection circuit-breaker 115A GV4P115N6"
Write a review
Evaluations will be activated after verification.