Motor protection circuit-breaker 3,5A GV4PE03N

Schneider Electric - GV4PE03N - Motor protection circuit-breaker 3,5A GV4PE03N
Photo source: fig. possibly similar
GV4PE03N 3606481310248 EAN/GTIN DE 33842582 WEEE

30,162.41₹ excl. VAT
53,526.66₹ (-43.65% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Motor protection switch 3.5A 3P 50kA GV4PE03N overload release current setting 1.4 ... 3.5A,... more
Motor protection circuit-breaker 3,5A GV4PE03N – Schneider Electric – 3606481310248: Motor protection switch 3.5A 3P 50kA GV4PE03N overload release current setting 1.4 ... 3.5A, setting range of the instantaneous short-circuit release 60 ... 60A, with thermal protection, sensitive to phase failure, electronic release technology, rated operating voltage 0 ... 690V, rated continuous current Iu 3.5A , rated operational power at AC-3, 230 V 0.75 kW, rated operational power at AC-3, 400 V 1.5 kW, connection type main circuit screw connection, design of the actuating element rocker arm, device design complete device in the housing, number of poles 3, rated limiting short-circuit breaking current Icu at 400 V, AC 50kA , Degree of protection (IP) IP40, height 155mm, width 81mm, depth 116mm, motor protection switch TeSys GV4 with thermal and magnetic tripping from 2A to 115A nominal current load. These devices are easy to operate and set up, with a compact and ergonomic design and for the highest requirements of up to 50kA in the area of low-voltage switchgear. Equipped with a toggle lever for easy operation and maintenance-free EverLink clamping technology.
... more
Overload release Current setting 49,86 mm
With thermal protection yes
Phase failure sensitive yes
Release system electronic
Rated operating voltage 690V
Rated continuous current Iu 3.5 A
Rated operating power at AC-3, 400V 1.5 kW
Connection type main circuit Screw
Execution of the actuating element Rocker arm
Device construction Complete device in the housing
With integrated auxiliary switch no
With integrated undervoltage release no
Number of poles 3
IP protection) IP40
Height 155 mm
Width 81 mm
Depth 116 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Motor protection circuit-breaker 3,5A GV4PE03N"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.