Lightning barrier 230V AC - Surge protection device 230V 3-pole VF230-AC/DC

VF230-AC/DC 5097650 4012195578161 EAN/GTIN DE 64419409 WEEE

Our best price
5,431.26₹ excl. VAT
10,109.79₹ (-46.28% RRP***)

5-6 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Lightning barrier 230V AC VF230-AC/DC Type of mounting DIN rail TH35, rated voltage AC 230V,... more
Lightning barrier 230V AC - Surge protection device 230V 3-pole VF230-AC/DC – OBO – 5097650 – 4012195578161: Lightning barrier 230V AC VF230-AC/DC Type of mounting DIN rail TH35, rated voltage AC 230V, rated voltage DC 230V, maximum continuous voltage AC 255V, maximum continuous voltage DC 350V, rated load current 20A, rated discharge current (8/20) (LN) 2.5kA, total discharge current (8/ 20) (L+N-PE) 7kA, protection level 1.4kV, protection level LN 1kV, protection level L-PE/N-PE 1.4kV, number of poles 3, optical signaling on the device, max. 2.5mm², max. conductor cross-section flexible (finely stranded) 2.5mm², test class type 3, degree of protection (IP) IP20, fine-wire protection type 3 according to EN 61643-11 (D according to VDE 0675 part 6-11). Suitable for DC and AC voltage systems. With optical function display and easy-to-install, screwless connection terminals. In the space-saving 17.5 mm pitch, Y circuit. Application: Universal use on 35 mm top-hat rails in standard distributor housings.
... more
Rated voltage AC 230V
Rated voltage DC 230V
Highest continuous voltage AC 255V
Highest continuous voltage DC 350V
Nominal load current 20 A
Nominal discharge current (8/20) (LN) 2.5 kA
Total discharge current (8/20) (L + N-PE) 7 kA
Protection level 1.4 kV
Protection level LN 1 kV
Protection level L-PE / N-PE 1.4 kV
Number of poles 3
Mounting DIN rail TH35
With telecommunication contact no
Signaling on the device optical
Test class type 3 yes
With noise filter no
IP protection) IP20