Individual room limitation RS485 bus actuator - Heating actuator for home automation FAE14SSR

FAE14SSR 30014029 4010312314173 EAN/GTIN DE 30298319 WEEE

Our best price
4,633.04₹ excl. VAT
6,287.90₹ (-26.32% RRP***)

5-6 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Individual room limitation RS485 bus actuator FAE14SSR bus system radio bus, other bus systems... more
Individual room limitation RS485 bus actuator - Heating actuator for home automation FAE14SSR – Eltako – 30014029 – 4010312314173: Individual room limitation RS485 bus actuator FAE14SSR bus system radio bus, other bus systems without, radio bidirectional, mounting type REG, width in modular units 1, with bus coupling, bus module removable, manipulated variable constant, manipulated variable switching, manual switching, number of binary inputs 0, max. switching current (resistive load) 4A, number of outputs 2, max. output current 1.7A, switching voltage 230 ... 230V, degree of protection (IP) IP20, noiseless individual room control with 2 channels, 400W. 2 solid-state relays not potential-free. Bidirectional. Standby loss only 0.1 watts. Connection to the Eltako RS485 bus. Bus cross-wiring and power supply with jumper. If both relays are switched on, 0.4 watts are required. The nominal switching capacity of 400W applies to one contact and also as the sum of both contacts. From production week 51/17 with automatic electronic excess temperature switch-off. With a load < 1W, a GLE must be connected in parallel to the load. The sensors are first taught in using the rotary switches. The channels can either be taught in together or separately. If FBH and wireless pushbutton are taught in, the last telegram received is always valid. In the event of movement, an FBH switches off a setback mode selected with the radio button. If a radio button is taught in, the assignment of the 4 buttons is fixed.
... more
Bus system KNX no
Bus system KNX radio no
Bus system radio bus yes
Bus system LON no
Bus system Powernet no
Other bus systems without
Radio bidirectional yes
Mounting REG
Width in division units 1
With bus coupling yes
Bus module removable yes
Control variable steady yes
Switching manipulated variable yes
Valve protection function no
Manual gearshift yes
Max. Switching current (resistive load) 4 A
Number of exits 2
Max. Output current 1.7 A
Switching voltage 230V
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Individual room limitation RS485 bus actuator - Heating actuator for home automation FAE14SSR"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.