The following 7500 products have been found matching your search "Insulation":

Item/s (7500)

Categories | Others (10)

Found in manufacturer pages: 1

Fischer DE - Most people will know the Fischer company for their ubiquitous fastening technology. Insulation anchors, impact nails, nail anchors, liquid anchors, universal anchors, aerated concrete anchors, screws, assembly anchors, toggle anchors, construction silicone, plasterboard anchors, clamps, fastening loops and perforated tape are just a few of the products that are available here in the eibabo® technology store and with which the company is united worldwide made names. Fastening technology is also by far the company's largest business area. It includes many thousands of products and is primarily aimed at the construction industry and the private do-it-yourself market. But the company is also active in other areas. These include Fischertechnik System Spielzeuge, Fischer Automotive Systems and Fischer Prozessberatung. The Fischertechnik toys have been around since 1965 and were intended to make the functionality of the technology understandable to children in a playful way. The automotive sector is the company's third major business area. As a specialist for system solutions in vehicle interiors, it supplies automobile manufacturers with components such as ventilation nozzles or cup holders. The company was founded by Artur Fischer in 1948 and initially manufactured electric lighters and loom switches. The development of the very successful S-Dowel in 1958 laid the foundation for the fastening technology product group that is so successful today. Fischer Holding GmbH & Co. KG is now represented by more than 50 national companies in around 40 countries and employs more than 5000 people worldwide. Production sites are in Argentina, Brazil, China, Germany, Italy, Serbia, the Czech Republic, the USA and Vietnam. The company exports to 120 countries, but the eibabo® shops from eibmarkt® ship worldwide as the company's major sales partner. The company headquarters are in Waldachtal.

Found in shop categories: 9

Insulation monitoring device - How does an insulation monitoring device work and where do I have to use it? What does the device protect against and what advantages does it offer me? Read here why the correct insulation of an electrical system is an essential prerequisite for its safe operation. Protect yourself and your system with high-quality measuring devices and reliable testing technology from the eibabo® online shop.The History of Insulation Monitoring DevicesThe first insulation monitoring device was invented by Walther Hans Bender in Frankfurt/Oder in 1939 and a patent was applied for. It was a device for three-phase systems in brown coal mining. In 1952 the 'Isometer' was protected as a trademark and has belonged to Bender GmbH & Co. KG ever since.Image: Dold IL5880.12 insulation monitorHow does an insulation monitoring device work?An insulation monitoring device is also referred to as a ground fault monitoring device. Connect this between your active power lines and the earth line. With continuous insulation monitoring, you can discover weak points in the insulation of your electrical systems. These can be caused, among other things, by moisture or by age-related fatigue of the material. You want to detect a problem like this before voltage breakdown occurs. Voltage breakdown will damage the insulator and cause sparks or arcing, which can lead to power failures, fires, property damage, and personal injury.The device sends a measuring voltage to your system and monitors it. If there is a ground fault, the measuring circuit between the mains line and the ground is closed. A measuring current proportional to the earth fault thus occurs. A voltage drop occurs at the measuring resistor of the device. Conversely, this means that the insulation resistance of the system is reduced. The insulation monitor registers the change and evaluates it. It is not only the resistance itself that is important, but also its course over time. In the case of undamaged insulation, the insulation resistance asymptotically approaches a certain reference value. term asymptoteA value behaves asymptotically if, over time, it approaches a reference value without ever reaching it. If the insulation resistance falls below the reference value, this is an indication of the increase in the conductivity of the insulator. From this it can be concluded that the insulator has changed chemically due to external influences or that its material is gradually enriched with decomposition substances. If a critical point is reached, the device sends a message. This allows you to recognize the deterioration of the technical condition of the insulation at an early stage and to take the appropriate steps for repair or maintenance in good time.Where is the use of an insulation monitoring device required?The measurement of the insulation resistance is used in local low-voltage networks without an operationally grounded star point (so-called IT power supplies).For explanationBasically, low-voltage systems are divided into TN systems, TT systems and IT systems. The main difference lies in the way of grounding. While residual current is used for monitoring in TN systems, insulation monitoring devices are used in IT systems.Modern insulation monitoring devices have a history memory and record the insulation resistance measurements. The data can be called up later and serve as suitable monitoring evidence during controls.What are the advantages of insulation monitoring devices?With insulation monitoring devices, you continuously monitor safety-relevant circuits for residual currents and residual currents. This results in a number of advantages in daily use:Measurement without switching off ongoing operationsReducing the risk of failure and increasing the availability of monitored electrical systemsReduction of electromagnetic interferenceReducing the risk of fireSaving of time-consuming and expensive maintenance and repairs You also prevent the safety of people and machines and thus avoid accidents, property damage and personal injury.Which manufacturers offer high-quality and reliable insulation monitoring devices?In the eibabo® technology store you only get quality goods from well-known manufacturers. These include ABB, Bender, Dold, Eaton, Pilz, Schneider Electric and Siemens. As a leading specialist center for electrical installations, lighting and smart home, we offer a huge selection as well as:top conditionsmany secure payment methodsshort delivery timeworldwide shippingshipment trackingaccommodating complaints handling   Catalogue content:In this eibabo® catalogue Relays > Insulation and earth fault monitoring relay you will find items from the following product groups:Item overview:Insulation monitoring deviceIso guardIsolation guardMeasuring relayMonitoring relayfrom the following manufacturers:Manufacturer overview catalogue Insulation monitoring device:ABBBenderDoldEatonPilzSiemens
Wire retainer - If cables are routed through self-drilled holes, especially if they are made of metal, there is always a risk that burrs and sharp edges will damage the insulation or even the current-carrying wires of a line or cable. In addition, in the rarest of cases, the hole produced is identical to the cable diameter. This creates a gap that allows debris to either enter or allow a loose cable to rub against the edge of the hole and become damaged over time. This is where the cable sockets from the eibabo technology store come to the rescue. These are available in different diameters, are made of soft plastic and thus close self-made holes, but also the openings at the ends of installation and empty pipes. Holes corresponding to the cable diameter can be punched through the pre-embossings attached to the cable insertion sockets, with which a tight seal of the cable bushing is then guaranteed.Catalogue content:In this eibabo® catalogue Cable and wire entry systems > Cable plug sealing clamp you will find items from the following product groups:Item overview:Blanking plugCable entryCable entry glandCable glandsCable inletCable plug sealing clampCable socketChoke stopperDouble membrane nozzleGag nippleGrommetInsertNozzlePipe socketPlastic cable glandPlastic nipplePlug-in cable glandPlug-in sealPlug-in socketPressure compensation elementPressure equalization nozzlePush-in pipe socketPush-in plugScrew-in nippleSealing nippleSealing plugSocketStepped socketfrom the following manufacturers:Manufacturer overview catalogue Wire retainer:CorningEatonHagerHenselIcotekJacobKaiserKleinhuisLappLegrand BticinoLützeMurrelektronikMurrplastikOBOPhoenixRSTSchneider ElectricSES SterlingSpelsbergWeidm?llerWiska
Conduit - plastic - Plastic installation tubes are used to house and protect cables and lines. At eibabo you can find a variety of suitable conduits and tubes for electrical installations. You can use our plastic installation tubes to protect cables and lines with sensitive insulation, such as data cables or network cables. Installation tubes can also be installed as empty tubes in ceilings, floors or walls. In this way, you ensure that you can perform subsequent installation work or replace lines without any extra effort. You can find plastic installation tubes in various metric sizes such as M16, M20, M25, M32, etc., and in different designs, geared to the intended use. We offer, e.g. installation tubes, empty conduits and empty electrical conduits for surface or flush-mounted installation and installation in concrete. If you need tubes for surface-mounted installation, you can choose, in our eibabo online shop, rigid installation tubes with slight compressive strength or high compressive strength as well as rigid installation tubes with flame-retardant properties. For the flush-mounted installation of electrical installation tubes, ideally, tubes with slight compressive strength are used. When used in concrete, you must select electrical installation tubes with medium compressive strength. These tubes are also provided with a protective plastic sheath. Make sure, that for safety reasons, only flame-retardant plastic installation tubes are installed in cavity walls. Convince yourself of our wide product range of installation tubes, plastic straight-lengths tubes, probe protection tubes, corrugated plastic tubes and Quick-Pipe Systems and open conduits.Catalogue content:In this eibabo® catalogue Installation pipes/cable protection tubes > Plastic installation tube you will find items from the following product groups:Item overview:Armored pipeBench radiatorChurch heatingConduitCorrugated tubeInstallation tubeInsulating pipeInsulating tubeMounting aid tubePew heaterPew radiatorPew spotlightPipePlastic armored tubePlastic corrugated pipePlastic electrical installation tubePlastic installation tubePlastic pipePlastic pole tubePlastic tubePolyolefin tubeProtective tubeQuartz heaterSupport elementTubeWeatherproof tubeWelding trackfrom the following manufacturers:Manufacturer overview catalogue Conduit - plastic:DeviEthermaFränkischeKaiserOBO
Inlet/outlet air valve - In addition to supply and exhaust valves, eibabo also offers you a wide range of devices and accessories for adjustable and fixed air outlets: exhaust valves, poppet valves made of plastic and metal, sound insulation elements, flaps, supply air poppet valves and automatic supply air units. Our high-quality products come from well-known manufacturers of ventilation systems such as Helios. Supply and exhaust valves are used as adjustable air outlets for air conditioning and ventilation systems in offices and administration buildings or in public buildings such as schools or hospitals. In addition, exhaust valves are suitable for ventilation and air conditioning of individual rooms without windows, such as bathrooms and toilets. In their function as exhaust elements, exhaust valves are an important component in modern, efficient and controllable room ventilation. There are exhaust valves, which are specially designed for central ventilation systems. Also, the poppet valve serves as supply air valve and exhaust valve for ventilation. Supply and exhaust valves are connected to the room lighting. But you can also activate ventilation with a separate switch. This permits an individual switching from basic ventilation to ventilation on demand and you can achieve significant energy savings with this simple solution. For most fans, you can set the basic ventilation by turning the plate starting from the fully closed state to the fully opened state.Catalogue content:In this eibabo® catalogue Air inlet/extraction units > Ventilation valve you will find items from the following product groups:Item overview:Air passage valveAir supply valveAir supply valve centralAir supply valve decentralizedBreather valveDesign valve socketExhaust nozzleExhaust valveExtractorInner bezelLocking flapOutdoor air outletOutside air elementRosetteSupply -/exhaust air valveSupply air automatSupply air grilleSupply air openingSupply air valveSupply air valve centralSupply air valve decentralizedSupply valveSupply/exhaust air valveToilet grilleValveVentilation accessoriesVentilation unitVentilation valvefrom the following manufacturers:Manufacturer overview catalogue Inlet/outlet air valve:Glen DimplexHeliosStiebel Eltron
Flexible electric cable - Did you know that there are different types of wiring in your house? Among other things, we distinguish electrical cables according to whether they have rigid or flexible core cables. Read here when which types are used and what you should consider when selecting flexible cables.How are flexible lines constructed?The conductive core of a flexible cable does not consist of a solid (monolithic) wire, but of many little wires twisted together. These little wires form an insulated core, the so-called stranded wire. Depending on the purpose of the product, several of these cores can be bundled together in a further sheath to form a cable. The most important selection criteria for such a product are:the number of insulated cores within the sheathing of a cable (this can be several dozen)the color and positioning of the cores within the sheathing of a cable (see twisted pair cable)the cross-section of the respective coresthe type and structure of the insulation and sheathing The number and cross-section of the cores determine the total power of the current that can be safely conducted. This is one of the most important features of a cable and is specified by the manufacturer at regular intervals on the outer insulation. We recommend using quality products from well-known manufacturers. Tolerances can occur with cheap no-name items, which usually have an adverse effect on the cross-section and thus impair the performance of the line. There are also differences in the shape of the wires or lines. Most often we encounter the round shape, but in some variants the outer shape can also be flat, for example. This affects the outer diameter and the possible uses.The type and structure of the insulation and sheathingInsulation appropriate for the application is the primary safety feature of an electrical cable. Their main task is:Protect people from contact with a live coreto protect the cable from mechanical damageto ensure a correct current flow without interference from the outsideto shield the environment from the influences of the line In a line, each core is separately insulated. This prevents contact between the electrical conductors in the cores and offers protection against mechanical damage. Another outer sheath holds all the components of the cable together and also protects the inner insulation from drying out, high humidity and other influences. Depending on the location and purpose of a line, different materials are used for the insulation. These should correspond to the expected mechanical, chemical and thermal influences. The UV radiation of the sun must also be taken into account. The following materials are therefore used most frequently in the area of classic household electrics:PVC ? inexpensive, flexible, low-wear, non-flammable and resistant to various chemical compounds, not suitable for high and very low temperaturesRubber - particularly flexible, suitable for medium to difficult operating conditions, resistant to low temperaturesPE - resistant to chemical compounds, pressure and low temperaturesSilicone ? particularly reliable at high temperatures up to around 200 °C, low mechanical strengthPUR ? high oil resistance and abrasion resistant immission and emissionCurrent-carrying cables generate magnetic fields. The immission protection protects the data flowing through the wire from external electromagnetic influences. The emission protection prevents the emission of electromagnetic interference signals through the line.The outer casing can consist of additional elements:Shielding made of metal foil or metal mesh as a barrier against immission and emission. These mainly include fault currents, radio waves, EM fields or radiation, which affect the transmission of signals in data lines.Armor as maximum line protection against mechanical damage.Cover made of (impregnated) cotton or silk to protect against mechanical damage, rot or for decorative purposes. Image: Various flexible linesWhat is the difference between flexible lines and rigid lines?Cables with rigid conductors are used for fixed installation in domestic installations. Cables with flexible conductors are used where you want to connect mobile consumers. Mobile consumers are, for example, floor lamps, coffee machines, radios or hair dryers. But why is that?Advantages and disadvantages of flexible, multi-core cables:high elasticity and flexibilitysmall power losseshigh quality circuitreliabilitypoor performance on HF networkshigh price In particular, the higher price and the more complex production of connections (e.g. due to the necessary cable lugs) stand in the way of the use of flexible cables for all areas of electrical installation. In comparison, solid conductors have the following advantages and disadvantages in these points:inexpensiveUse in HF networkseasier installationeasy connectionhigh rigidity, not very flexible, difficult handling You save money with solid conductors in fixed installation. However, the handling of rigid cables is too cumbersome for daily mobile use on electrical devices, extensions or distributors.Pliability of flexible linesThe number of cores and the diameter of the wires in a core determine the flexibility of the core of a cable. The standard DIN EN 60228 (VDE 0295) describes four classes of conductors: solid (i.e. single-core solid conductors), stranded, finely stranded and extra finely stranded. The thinner the wires, the easier it is to bend the line. TIPSingle-wire and multi-wire cables have different levels of flexibility. During operation, these should not be bent too much so that the core is not damaged. The rule of thumb for solid conductors is: The minimum bending radius should not be less than four to five times the diameter of the cable including the sheath. A line with an outer diameter of 11 mm should therefore not be bent below a radius of about 50 mm. Flexible cables are more flexible than solid cables. Their bending radius should not be less than three times the cable diameter.What is a stranded twisted pair?Information systems have become an integral part of life today. Telecommunications, the global Internet and television are part of our everyday lives. One of the most important components of such networks is the twisted pair line. This is a line consisting of four or eight copper wires. The cores of the twisted pair cables are offered as solid or in the form of stranded wires. The special thing about it is that the wires are twisted together in pairs. A shield increases the protection of the line against electromagnetic interference. Twisted pair cables are primarily intended for the transmission of digital information in Ethernet networks. twisted pair lines. The area of application is not only private houses and apartment buildings, but also commercial offices and industrial companies as well as public facilities such as schools and hospitals.What is the significance of the core colors in flexible cables?If you look at a typical flexible power supply cable, you will see strands of different colors in it. In Germany these are typically black, brown, blue, gray and green-yellow. In order to be able to use the individual wires correctly, you should know the meaning of the color coding. This is important so that other people can rely on the correct assignment of the colors during repairs, checks or changes. Installers derive the function of individual wires from this. Instructions are printed on the sheathing, which provide information about the number of wires and their diameter. The following rules apply to the colors of the wires in Germany and the EU: The basic colors are brown, blue and green-yellow. There are also the extended basic colors black and grey. Alternative colors are white, orange, red and purple.NoticeDepending on the manufacturer, country and type of cable, there are major deviations in the colors of the core insulation. Please use the standard applicable in your country.The following applies to Germany and large parts of Europe: the brown wire is phase 'L1' and is always used as the current-carrying line to the device. The blue wire is the 'N' neutral and carries the power back to the source. The green-yellow wire is intended for grounding. This is called the protective conductor 'PE'. The extended basic colors black and gray are used when it is a three-phase AC installation. The black wire represents phase 'L2', the gray wire represents phase 'L3'. The alternative colors of white, orange, red and purple are intended to complement certain installations.Which cross-section do I have to pay attention to with flexible cables?Flexible cables with stranded copper for normal household use start with a standard cross-section of 0.5 mm². The dimensions 0.75 mm², 1.5 mm² and 2.5 mm² are widespread. The cross-section you need depends on numerous conditions. These include:the type of current (direct current, alternating current)the level of the operating voltagethe amperagethe length of the linethe type of transferthe voltage dropthe phase angle These parameters result in a formula that can be used to calculate a cable cross-section. Due to the many variables, for safety reasons we do not give any general recommendations for the use of certain cross-sections at this point.Simply browse through our large eibabo® range. Here you will find flexible PVC hose lines, silicone lines, rubber lines or PUR lines at particularly reasonable prices.  Catalogue content:In this eibabo® catalogue Cables > Power cable < 1 kV, for moving application you will find items from the following product groups:Item overview:Control cableControl lineData cableData lineDevice connection cableExternal lineFuse boxHigh voltage cableHouse connection cableInsulating tubeLine jumperMachine control lineMeasurement lineMeasuring systemMedium voltage cableOvervoltage protectionPower cablePower control linePower lineRubber cableRubber hose lineServo lineSilicone cableSilicone lineSupply cableTrailing cableTrunk cable ringVoltage tapfrom the following manufacturers:Manufacturer overview catalogue Flexible electric cable:BachmannBarthelmeComelit GroupDiverseEatonElsproFaber KabelGlenHagerHartingHelukabelIgusLappkabelLeoni StuderLützeMurrelektronikPhoenixPilzScharnberger+Has.WaltherWaremaWeidmüllerWieland
Close filters
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
from to

1 From 625
No results were found for the filter!
RECOMMENDED
3D
Fluke - Fluke 1507 - Insulation tester 0,01...10000MOhm Fluke 1507
61,737.14₹ excl. VAT

*

Insulation tester 0,01...10000MOhm
Fluke
| Fluke 1507
RECOMMENDED
3D
Eaton - PXK-B16/1N/003-A - Residual current circuit breaker with line protection B 16A 1p + N, 30mA PXK-B16/1N/003-A
2,792.05₹ excl. VAT

*

plus shipping
(19,076.68₹ RRP***)
Residual current circuit breaker with line protection B 16A 1p + N, 30mA
Eaton
| PXK-B16/1N/003-A
RECOMMENDED
3D
Eaton - PXF-40/4/003-A - Residual current circuit breaker 40A, 4-pole, 30mA PXF-40/4/003-A
2,315.13₹ excl. VAT

*

plus shipping
(11,575.66₹ RRP***)
Residual current circuit breaker 40A, 4-pole, 30mA
Eaton
| PXF-40/4/003-A
RECOMMENDED
3D
Hager - ADS963D - Earth leakage circuit breaker with line protection, 1P + N, C-13A 30mA ADS963D
5,165.52₹ excl. VAT

*

plus shipping
(11,955.34₹ RRP***)
Earth leakage circuit breaker with line protection, 1P + N, C-13A 30mA
Hager
| ADS963D
RECOMMENDED
3D
Schneider Electric - A9Z21440 - Residual current circuit breaker, 4-pole, 40A 30mA type A A9Z21440
2,468.86₹ excl. VAT

*

plus shipping
(11,760.87₹ RRP***)
Residual current circuit breaker, 4-pole, 40A 30mA type A
Schneider Electric
| A9Z21440
RECOMMENDED
3D
Hager - ADS916D - Residual current circuit breaker with line protection, 1P + N, B-16A, 30mA ADS916D
4,007.03₹ excl. VAT

*

plus shipping
(11,436.75₹ RRP***)
Residual current circuit breaker with line protection, 1P + N, B-16A, 30mA
Hager
| ADS916D
RECOMMENDED
3D
Diverse - H07V-U 1,5 hbl Eca - Single core solid wire H07V-U 1,5 hbl Eca
2,201.23₹ excl. VAT

*

(For 100 Metre) plus shipping
Single core solid wire
Diverse
| H07V-U 1,5 hbl Eca
x 100 Metre
Add to wishlist
RECOMMENDED
3D
Diverse - H07V-U 1,5gn/geEca - Single-core wire H07V-U 1,5gn/geEca
2,201.23₹ excl. VAT

*

(For 100 Metre) plus shipping
Single-core wire
Diverse
| H07V-U 1,5gn/geEca
x 100 Metre
Add to wishlist
RECOMMENDED
3D
Diverse - H07V-K 1,5 sw Eca - Conductor strand fine-stranded H07V-K 1,5 sw Eca
2,107.70₹ excl. VAT

*

(For 100 Metre) plus shipping
Conductor strand fine-stranded
Diverse
| H07V-K 1,5 sw Eca
x 100 Metre
Add to wishlist
RECOMMENDED
3D
Diverse - H07V-K 1,5 hbl Eca - Wire finely stranded - Power cable < 1kV, fix installation H07V-K 1,5 hbl Eca
2,107.70₹ excl. VAT

*

(For 100 Metre) plus shipping
Wire finely stranded - Power cable < 1kV, fix installation
Diverse
| H07V-K 1,5 hbl Eca
x 100 Metre
Add to wishlist
RECOMMENDED
3D
Schneider Electric - A9D56616 - Residual current circuit breaker with line protection 16A B 30mA A A9D56616
2,902.25₹ excl. VAT

*

plus shipping
(12,779.52₹ RRP***)
Residual current circuit breaker with line protection 16A B 30mA A
Schneider Electric
| A9D56616
RECOMMENDED
3D
Doepke - DFS4 040-4/0,03-A EV - Residual current device DFS4 040-4/0,03-A EV
26,585.11₹ excl. VAT

*

plus shipping
(38,533.04₹ RRP***)
Residual current device
Doepke
| DFS4 040-4/0,03-A EV
1 From 625