Incremental encoder interface RS 422 - Fieldbus function-/technology module 750-631/000-004

WAGO - 750-631/000-004 - Incremental encoder interface RS 422 - Fieldbus function-/technology module 750-631/000-004
Photo source: fig. possibly similar
Photo source: fig. possibly similar
750-631/000-004 4050821248309 EAN/GTIN DE 40917098 WEEE

28,924.88₹ excl. VAT

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Incremental encoder interface RS 422 750-631/000-004 Supply voltage at DC 24... 24V Type of... more
Incremental encoder interface RS 422 - Fieldbus function-/technology module 750-631/000-004 – WAGO – 4050821248309: Incremental encoder interface RS 422 750-631/000-004 Supply voltage at DC 24... 24V Type of supply voltage DC Number of hardware interfaces Industrial Ethernet 0 Number of interfaces PROFINET 0 Number of hardware interfaces serial RS- 232 0, number of HW interfaces serial RS-422 1, number of HW interfaces serial RS-485 0, number of HW interfaces serial TTY 0, number of HW interfaces parallel 0, number of HW interfaces wireless 0, Number of HW interfaces USB 0 Number of HW interfaces others 0 Supports protocol for other bus systems System component Suitable for incremental value acquisition Suitable for absolute value acquisition Degree of protection (IP) IP20 Fieldbus connection via separate bus coupler possible, mounting rail mounting possible, explosion protection category for gas without, explosion protection category for dust without, width 24mm, height 64mm, depth 100mm, The terminal provides an interface for connecting any incremental encoder. A 16-bit counter with quadrature decoder and a 16-bit latch for the zero pulse can be read, set or activated. The meter reading is transmitted quickly and reliably to the PC, PLC and NC via the installed field bus. The Gate input allows the counter to be disabled. The voltage supply of the encoder can be tapped directly at terminal Ue/U0. The shield connection is routed directly to the DIN rail.
... more
Supply voltage at DC 24V
Voltage type of the supply voltage DC
Number of functions 2
Number of HW interfaces serial RS-422 1
With optical interface no
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
Radio standard GPRS no
Radio standard GSM no
Radio standard UMTS no
IO-Link master no
System component yes
Suitable for counting no
Suitable for weighing no
Suitable for temperature control no
Suitable for welding control no
Suitable for pressure control no
Suitable for NC no
Suitable for position detection yes
Suitable for CNC no
Suitable for SSI no
Suitable for incremental value acquisition yes
Suitable for absolute value acquisition yes
Suitable for flow control no
Suitable for flow measurement no
Suitable for railway control no
Suitable for cam control no
Suitable for flying saw no
Suitable for multi-axis control no
Suitable for single-axis control no
Suitable for multi-axis positioning no
Suitable for single-axis positioning no
Function block restart interlock no
Function block automatic reset no
Contactor control function block no
Function block EMERGENCY STOP no
Function block acknowledgment button no
Function block two-hand circuit no
Function block operating mode selection no
Function block access control no
IP protection) IP20
Frequency measurement no
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Explosion protection category for gas without
Explosion protection category for dust without
Width 24 mm
Height 100 mm
Depth 69.8 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Incremental encoder interface RS 422 - Fieldbus function-/technology module 750-631/000-004"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.