Power cable - Low voltage power cable 3x1,5mm² 0,6/1kV NHXCH E30 3x 1,5RE1

Diverse - NHXCH E30 3x 1,5RE1 - Power cable - Low voltage power cable 3x1,5mm² 0,6/1kV NHXCH E30 3x 1,5RE1
Photo source: fig. possibly similar
Photo source: fig. possibly similar
NHXCH E30 3x 1,5RE1 NHXCH E30 3x 1,5RE/1,5 S

Our best price
601.01₹ excl. VAT

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
NHXCH E30 3x 1.5RE/1.5 S safety cable E30 NHXCH E30 3x 1.5RE1, conductor material=copper,... more
Power cable - Low voltage power cable 3x1,5mm² 0,6/1kV NHXCH E30 3x 1,5RE1 – Diverse – NHXCH E30 3x 1,5RE/1,5 S: NHXCH E30 3x 1.5RE/1.5 S safety cable E30 NHXCH E30 3x 1.5RE1, conductor material=copper, conductor nominal cross section=1.5 mm², conductor class=class 1 = solid, conductor shape=round , core number=3, core identification=color, protective conductor=no, screen=no, drain wire=no, lead sheath=no, concentric conductor=copper, concentric conductor nominal cross-section=1.5 mm², reinforcement=no, sheath material= Polyolefins, jacket color=orange, insulation integrity=FE 180, functional integrity=E 30, outer diameter approx.=13 mm, min. permissible bending radius, stationary use/permanently installed=156 mm, permissible max. conductor temperature=90 °C, perm. External cable temperature during assembly/handling=-5..90 °C, nominal voltage U0=0.6 kV, nominal voltage U=1 kV, based on DIN VDE 0266. Safety cable with improved behavior in the event of fire. Use wherever special protection against fire and fire damage is required for people and property and high safety requirements have to be met. They may be laid indoors. When laying outdoors, protection against direct sunlight must be provided. Direct laying in the ground and water is only permitted using a protective tube. These cables meet the requirements for functional integrity E30 according to DIN 4102 Part 12. Permissible operating temperature on the conductor 90 °C.
... more
Conductor material Copper
Conductor cross-section 1.5 mm²
Conductor category Kl.1 = solid
Head shape round
Number of cores 3
Core identification Color
With protective conductor no
Umbrella no
Drain wire no
Lead sheath no
Concentric conductor Copper
Concentric conductor nominal cross-section 1.5 mm²
Reinforcement no
jacket material polyolefins
Coat Color orange
Insulation FE 180
Integrity E30
Outer diameter approx. 13 mm
Mass 320 kg/km
Permitted max. conductor temperature 90 °C
Rated voltage U0 0.6 kV
Rated voltage U 1 kV