FI/LS combination - Earth leakage circuit breaker C6/0,1A DRCBO4C06/0,10/3N-B+

Doepke - DRCBO4C06/0,10/3N-B+ - FI/LS combination - Earth leakage circuit breaker C6/0,1A DRCBO4C06/0,10/3N-B+
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DRCBO4C06/0,10/3N-B+ 09948371 4014712265981 EAN/GTIN

68,123.18₹ excl. VAT
90,541.70₹ (-24.76% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Number of poles (total)=4, Number of protected poles=3, Rated voltage=400 V, Rated insulation... more
FI/LS combination - Earth leakage circuit breaker C6/0,1A DRCBO4C06/0,10/3N-B+ – Doepke – 09948371 – 4014712265981: Number of poles (total)=4, Number of protected poles=3, Rated voltage=400 V, Rated insulation voltage Ui=440 V, Rated impulse withstand voltage Uimp=4 kV, Rated current=6 A, Rated fault current=0,1 A, Leakage current type=B+, Current limiting class=3, Rated short-circuit breaking capacity according to EN 61009=6 kA, Rated short-circuit breaking capacity Icn according to EN 61009-1=6 kA, Disconnection characteristic=Short-time delayed, Surge current capacity=3 kA, Voltage type=AC, Frequency=50 Hz, Release characteristic=C, Concurrently switching neutral conductor=yes, With interlocking device=no, Over voltage category=3, Pollution degree=2, Ambient temperature during operating=-25..40 °C, Width in number of modular spacings=4,5, Built-in depth=67 mm, Flush-mounted installation=no, Anti-nuisance tripping version=no, Degree of protection (IP)=IP20, Connectable conductor cross section solid-core=1..35 mm², Connectable conductor cross section multi-wired=1..25 mm²
... more
Number of poles (total) 4
Number of secured poles 3
Rated voltage 400V
Rated insulation voltage Ui 440V
Rated impulse withstand voltage Uimp 4 kV
Rated current 6A
Rated fault current 0.1 A
Fault current type B+
Limiting class 3
Rated breaking capacity according to EN 61009 6 kA
turn-off characteristic time-delayed
Surge current resistance 3 kA
Voltage AC
Frequency 50 Hz
Release characteristic C
Coupling neutral conductor yes
With locking device no
Overvoltage category 3
Pollution degree 2
Width in division units 4.5
Depth 67 mm
Flush mounting no
False triggering protection no
IP protection) IP20