Analog input module 2 inputs - Fieldbus analogue module 2 In / 0 Out XN-2AI-THERMO-PI

XN-2AI-THERMO-PI 140068 7640130120129 EAN/GTIN DE 92318050 WEEE

Our best price
28,904.00₹ excl. VAT

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Analog input module 2 inputs XN-2AI-THERMO-PI supply voltage at AC 50 Hz 0V, supply voltage at AC... more
Analog input module 2 inputs - Fieldbus analogue module 2 In / 0 Out XN-2AI-THERMO-PI – Eaton – 140068 – 7640130120129: Analog input module 2 inputs XN-2AI-THERMO-PI supply voltage at AC 50 Hz 0V, supply voltage at AC 60 Hz 0V, supply voltage at DC 20.4 ... 28.8V, type of supply voltage DC, input, thermocouple, input signal configurable, resolution of the analog inputs 16 bits, resolution of the analog outputs 0 bits, number of analog inputs 2, number of analog outputs 0, analog inputs configurable, analog outputs configurable, number of HW interfaces Industrial Ethernet 0, number of interfaces PROFINET 0, number of HW interfaces serial RS-232 0, number of HW interfaces serial RS-422 0, number of HW interfaces serial RS-485 0, number of HW interfaces serial TTY 0, number of HW interfaces parallel 0, number of HW interfaces wireless 0, number of HW interfaces USB 0, number of HW interfaces other 1, system component, degree of protection (IP) IP20, design of the electrical connection screw/spring-loaded connection , fieldbus connection possible via separate bus coupler, DIN rail mounting possible, SIL according to IEC 61508 without, performance level according to EN ISO 13849-1 without, explosion protection category for gas without, explosion protection category for dust without, width 12.6mm, height 74mm, depth 55 ,4mm, The XI/ON standard I/O system offers the right I/O solution for every application due to its high degree of modularity and the large variety of functions. Pluggable modules, quick module change (hot swap), wiring on base module screw or tension spring, mechanical coding of the modules. The standard gateways serve the bus systems CANopen, Profibus-DP, DeviceNet and Ethernet.
... more
Supply voltage at AC 50 Hz 0 V
Supply voltage at AC 60 Hz 0 V
Supply voltage at DC 20.4..28.8 V
Voltage type of the supply voltage DC
Entrance, electricity no
Input, voltage no
Entrance, resistance no
Entrance, resistance thermometer no
Input, thermocouple yes
Input signal configurable yes
Resolution of the analog inputs 16 bits
Output, electricity no
Output, voltage no
Output signal configurable no
Resolution of the analog outputs 0 bit
Number of analog inputs 2
Analog inputs configurable yes
Analog outputs configurable yes
Number of HW interfaces other 1
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Supports protocol for other bus systems yes
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
Radio standard GPRS no
Radio standard GSM no
Radio standard UMTS no
IO-Link master no
System component yes
IP protection) IP20
Protection class (NEMA) 1
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
SIL according to IEC 61508 without
Performance level according to EN ISO 13849-1 without
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Explosion protection category for gas without
Explosion protection category for dust without
Width 12.6 mm
Height 74.1 mm
Depth 55.4 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Analog input module 2 inputs - Fieldbus analogue module 2 In / 0 Out XN-2AI-THERMO-PI"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.