KEL Fe/CuNi LX 4x1.5 DIN 0155001 - Thermocouple cable2x2x1,5mm² 0155001 R100

Lappkabel - 0155001 R100 - KEL Fe/CuNi LX 4x1.5 DIN 0155001 - Thermocouple cable2x2x1,5mm² 0155001 R100
Photo source: fig. possibly similar
0155001 R100 0155001/100 4044774675596 EAN/GTIN DE 14831145 WEEE

Our best price
153,452.71₹ excl. VAT
(For 100 Metre) plus shipping

16-17 days* (IND)

x 100 Metre
Add to wish list
Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
KEL Fe/CuNi LX 4x1.5 DIN 0155001 R100 Conductor material Conductor 2 CuNi, conductor... more
KEL Fe/CuNi LX 4x1.5 DIN 0155001 - Thermocouple cable2x2x1,5mm² 0155001 R100 – Lappkabel – 0155001/100 – 4044774675596: KEL Fe/CuNi LX 4x1.5 DIN 0155001 R100 Conductor material Conductor 2 CuNi, conductor cross-section 1.5mm², number of thermocouples 2, material of core insulation other, specification core insulation other, screen over stranded element without, screen over stranded without, sheath material Polyvinyl chloride (PVC), specification jacket material other, jacket color blue, outer diameter approx. 8.2mm, min. permissible bending radius, flexible use/free movement 102.5mm, min. permissible bending radius, stationary use/fixed installation 49.2mm, reaction to fire class according to EN 13501-6 without, smoke development class according to EN 13501-6 without, dripping behavior class according to EN 13501-6 without, acid development class according to EN 13501-6 without, Version Y: - Finely stranded conductor alloy - PVC core insulation - Cores stranded in layers - PVC outer sheath, version SY: - Structure like version Y - Additional galvanized steel mesh - PVC outer sheath, version ST: - Structure like version Y - Cores twisted in pairs, pairs twisted in layers - Aluminum foil screen + drain wire - PVC outer jacket, construction example for PVC-PVC-S-PVC: - PVC core insulation - PVC inner jacket - steel wire mesh - PVC outer jacket, construction example for PVC-ST-PVC: - PVC core insulation - static foil screen - PVC outer jacket, color coding DIN 43710 Negative conductor and sheath: Fe/CuNi: blue NiCr/Ni: green PtRh/Pt: white Positive conductor: each red IEC 60 584 Positive conductor and sheath: Fe/CuNi: black NiCr/Ni: green PtRh/Pt: orange Negative conductor: each white, Thermal conductor alloys are marked with an X, e.g. JX (Fe/CuNi) Compensating conductor alloys are marked with a C, e.g. KCA (NiCr/Ni),
... more
Conductor material conductor 2 CuNi
Conductor cross-section 1.5 mm²
Number of thermo pairs 2
Core insulation material other
Specification Core insulation other
Screen over stranding element without
Screen over stranding without
Reinforcement no
jacket material Polyvinyl chloride (PVC)
Specification of jacket material other
Coat Color blue
Outer diameter approx. 8.2 mm
Fire behavior class according to EN 13501-6 without
Smoke development class according to EN 13501-6 without
Drip behavior class according to EN 13501-6 without
Acid development class according to EN 13501-6 without