KNL-SY NiCr/Ni KCA 4x1.5 DIN 0156501 - Thermocouple cable2x2x1,5mm² 0156501 T500

Lappkabel - 0156501 T500 - KNL-SY NiCr/Ni KCA 4x1.5 DIN 0156501 - Thermocouple cable2x2x1,5mm² 0156501 T500
Photo source: fig. possibly similar
0156501 T500 0156501/500 4044774676104 EAN/GTIN DE 14831145 WEEE

1,157,595.19₹ excl. VAT
(For 500 Metre) plus shipping

16-17 days* (IND)

x 500 Metre
Add to wish list
Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
KNL-SY NiCr/Ni KCA 4x1.5 DIN 0156501 T500 conductor material conductor 2 CuNi, conductor... more
KNL-SY NiCr/Ni KCA 4x1.5 DIN 0156501 - Thermocouple cable2x2x1,5mm² 0156501 T500 – Lappkabel – 0156501/500 – 4044774676104: KNL-SY NiCr/Ni KCA 4x1.5 DIN 0156501 T500 conductor material conductor 2 CuNi, conductor cross-section 1.5mm², number of thermal pairs 2, material of core insulation other, specification of core insulation other, screen over stranded element without, screen over stranded without , reinforcement, jacket material polyvinyl chloride (PVC), specification jacket material other, jacket color green, outer diameter approx. 11.4mm, min. permissible bending radius, flexible use/free movement 171mm, min. permissible bending radius, stationary use/fixed installation 68.4mm , Fire behavior class according to EN 13501-6 without, smoke development class according to EN 13501-6 without, dripping behavior class according to EN 13501-6 without, acid development class according to EN 13501-6 without, Version Y: - Finely stranded conductor alloy - PVC core insulation - Cores stranded in layers - PVC outer sheath , Version SY: - Construction like Version Y - Additional galvanized steel mesh - PVC outer sheath, Version ST: - Construction like Version Y - Cores twisted in pairs, pairs in La stranded - aluminum foil screen + drain wire - PVC outer jacket, construction example for PVC-PVC-S-PVC: - PVC core insulation - PVC inner jacket - steel wire mesh - PVC outer jacket, construction example for PVC-ST-PVC: - PVC core insulation - static foil screen - PVC outer jacket, Color coding DIN 43710 negative conductor and sheath: Fe/CuNi: blue NiCr/Ni: green PtRh/Pt: white positive conductor: each red IEC 60 584 positive conductor and sheath: Fe/CuNi: black NiCr/Ni: green PtRh/Pt: orange negative conductor: each white, thermal conductor alloys are marked with an X, e.g. JX (Fe/CuNi) compensating conductor alloys are marked with a C, e.g. KCA (NiCr/Ni),
... more
Conductor material conductor 2 CuNi
Conductor cross-section 1.5 mm²
Number of thermo pairs 2
Core insulation material other
Specification Core insulation other
Screen over stranding element without
Screen over stranding without
Reinforcement yes
jacket material Polyvinyl chloride (PVC)
Specification of jacket material other
Coat Color green
Outer diameter approx. 11.4 mm
Fire behavior class according to EN 13501-6 without
Smoke development class according to EN 13501-6 without
Drip behavior class according to EN 13501-6 without
Acid development class according to EN 13501-6 without

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "KNL-SY NiCr/Ni KCA 4x1.5 DIN 0156501 - Thermocouple cable2x2x1,5mm² 0156501 T500"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.