Fire protection duct I90/E30 direct installation - Fire-resistant duct I90 E30 BSKD09-K0511

OBO - BSKD09-K0511 - Fire protection duct I90/E30 direct installation - Fire-resistant duct I90 E30 BSKD09-K0511
Photo source: fig. possibly similar
Photo source: fig. possibly similar
BSKD09-K0511 7215139 4012197308209 EAN/GTIN DE 64419409 WEEE

Our best price
15,655.99₹ excl. VAT
22,888.56₹ (-31.6% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Fire protection duct I90/E30 direct installation BSKD09-K0511 Fire resistance class I -... more
Fire protection duct I90/E30 direct installation - Fire-resistant duct I90 E30 BSKD09-K0511 – OBO – 7215139 – 4012197308209: Fire protection duct I90/E30 direct installation BSKD09-K0511 Fire resistance class I - installation duct 90, fire resistance class E - functional integrity 30, external height 110mm, external width 190mm, length 1000mm, usable cross section 6600mm², number of flammable sides 3, material of the insulating material: fiberglass lightweight concrete, casing without, color grey, partition walls possible, screw cover fastening, fire protection duct made of water- and frost-resistant lightweight fiberglass concrete of building material class A1 in accordance with EN 13501-1 for fire-safe laying of cables in escape and rescue routes and for maintaining the functionality of safety-relevant systems. Classification I90 as an I-duct according to DIN 4102 Part 11 and classification E30 as an E-duct according to DIN 4102 Part 12. Installation of the duct directly on walls or under ceilings. Includes countersunk screws and sealing strips.
... more
Fire resistance class I - installation duct 90
Fire resistance class E - functional integrity 30
External height 110 mm
External width 190 mm
Length 1000 mm
Usable cross-section 6600 mm²
Number of flammable pages 3
Jacket without
Colour gray
Partitions possible yes
With bottom perforations no
Cover attachment screw together