Fieldbus controller Ethernet TCP/IP 10MB - Modular PLC CPU-module PLC-CPU-module 750-842

750-842 4045454527198 EAN/GTIN DE 40917098 WEEE

Our best price
39,698.52₹ excl. VAT

5-6 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Supply voltage for DC 24V, Voltage type of the supply voltage DC, Type modular, Number of HW... more
Fieldbus controller Ethernet TCP/IP 10MB - Modular PLC CPU-module PLC-CPU-module 750-842 – WAGO – 4045454527198: Supply voltage for DC 24V, Voltage type of the supply voltage DC, Type modular, Number of HW interfaces, Industrial Ethernet 1, Number of HW interfaces, Industrial Ethernet 1, With optical interface no, Supports protocol for TCP/IP no, Supports protocol for PROFIBUS no, Number of HW interfaces, other 1, Supports protocol for CAN no, With optical interface no, Supports protocol for INTERBUS no, Supports protocol for TCP/IP yes, Supports protocol for ASI no, Supports protocol for PROFIBUS no, Supports protocol for KNX no, Supports protocol for CAN no, Supports protocol for MODBUS yes, Supports protocol for INTERBUS no, Supports data highway protocol no, Supports protocol for ASI no, Supports protocol for DeviceNet no, Supports protocol for KNX no, Supports protocol for SUCONET no, Supports protocol for MODBUS no, Supports protocol for LON no, Supports data highway protocol no, Supports protocol for PROFINET IO no, Supports protocol for DeviceNet no, Supports protocol for PROFINET CBA no, Supports protocol for SUCONET no, Supports protocol for SERCOS no, Supports protocol for LON no, Supports protocol for SERCOS no, Supports protocol for Ethernet/IP no, Supports protocol for PROFINET IO no, Supports protocol for PROFINET CBA no, Supports protocol for DeviceNet Safety no, Supports protocol for INTERBUS safety no, Supports protocol for Ethernet/IP no, Supports protocol for PROFIsafe no, Supports protocol for SafetyBUS p no, Supports protocol for DeviceNet Safety no, Supports protocol for INTERBUS safety no, Wireless standard Bluetooth no, Supports protocol for PROFIsafe no, Wireless standard WLAN 802.11 no, Supports protocol for SafetyBUS p no, Wireless standard GPRS no, Wireless standard GSM no, Wireless standard Bluetooth no, Wireless standard UMTS no, Wireless standard WLAN 802.11 no, IO link master no, Wireless standard GPRS no, System component yes, Wireless standard GSM no, Redundancy no, Wireless standard UMTS no, With display no, IO link master no, Memory type R.A.M., System component yes, Memory size 128 kbytes, Program memory extension possible no, Mounting rail installation possible yes, Wall/direct mounting possible no, Front installation possible no, Rack mounting possible no, Suitable for safety functions no, Associated equipment (Ex ia) no, Associated equipment (Ex ib) no, Mounting rail installation possible yes, Wall/direct mounting possible no, Width 51 mm, Front installation possible no, Height 65 mm, Rack mounting possible no, Depth 100 mm, Suitable for safety functions no, Associated equipment (Ex ia) no, Associated equipment (Ex ib) no, Explosion protection category for gas without, Explosion protection category for dust without, Width 51 mm, Height 65 mm, Depth 100 mm
... more
Supply voltage at DC 24V
Voltage type of the supply voltage DC
Execution modular
Number of HW interfaces Industrial Ethernet 1
With optical interface no
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS yes
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP yes
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Supports protocol for DNP3 no
Supports protocol for IEC 60870 no
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
Radio standard GPRS no
Radio standard GSM no
Radio standard UMTS no
LTE no
IO-Link master no
System component yes
Redundancy no
With display no
Memory Type FLASH
Memory size 128 kbytes
Program memory extension possible no
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Width 50.5 mm
Height 100 mm
Depth 71.1 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Fieldbus controller Ethernet TCP/IP 10MB - Modular PLC CPU-module PLC-CPU-module 750-842"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.