Climate control package pre-programmed - Heating actuator for bus system CPAD-00/231

Eaton - CPAD-00/231 - Climate control package pre-programmed - Heating actuator for bus system CPAD-00/231
Photo source: fig. possibly similar
Photo source: fig. possibly similar
CPAD-00/231 9010238139787 EAN/GTIN DE 92318050 WEEE

18,743.72₹ excl. VAT
27,867.56₹ (-32.74% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Bus system KNX=no, Bus system KNX radio=no, Bus system radio frequent=yes, Bus system LON=no, Bus... more
Climate control package pre-programmed - Heating actuator for bus system CPAD-00/231 – Eaton – 9010238139787: Bus system KNX=no, Bus system KNX radio=no, Bus system radio frequent=yes, Bus system LON=no, Bus system Powernet=no, Other bus systems=xComfort, Radio frequent bidirectional=yes, Mounting method=Flush mounted (plaster), Width in number of modular spacings=3, With bus connection=yes, Bus module detachable=no, Correcting variable consistent=yes, Correcting variable switching=no, Valve protection function=no, Manual switch=no, Max. switching current (resistive load)=10 A, Number of outputs=1, Max. output current=10 A, Switching voltage=196..253 V, Degree of protection (IP)=IP20, Min. depth of built-in installation box=18 mm
... more
Bus system KNX no
Bus system KNX radio no
Bus system radio bus yes
Bus system LON no
Bus system Powernet no
Other bus systems xComfort
Radio bidirectional yes
Mounting Flush
Width in division units 3
With bus coupling yes
Bus module removable no
Control variable steady yes
Switching manipulated variable no
Valve protection function no
Manual gearshift no
Max. Switching current (resistive load) 10 A
Number of exits 1
Max. Output current 10 A
Switching voltage 196..253 V
IP protection) IP20
Min. depth of the device socket 18 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Climate control package pre-programmed - Heating actuator for bus system CPAD-00/231"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.