SpaceLogic KNX Fan Coil 0-10V controller - KNX Heating actuator for bus system MTN6730-0003

Schneider Electric - MTN6730-0003 - SpaceLogic KNX Fan Coil 0-10V controller - KNX Heating actuator for bus system MTN6730-0003
Photo source: fig. possibly similar
MTN6730-0003 3606481029904 EAN/GTIN DE 33842582 WEEE

17,896.55₹ excl. VAT
24,151.88₹ (-25.9% RRP***)

16-17 days* (IND)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
SpaceLogic KNX Fan Coil 0-10V controller MTN6730-0003 bus system KNX, bus system KNX radio, other... more
SpaceLogic KNX Fan Coil 0-10V controller - KNX Heating actuator for bus system MTN6730-0003 – Schneider Electric – 3606481029904: SpaceLogic KNX Fan Coil 0-10V controller MTN6730-0003 bus system KNX, bus system KNX radio, other bus systems other, mounting type REG, width in division units 4, with bus coupling, bus module removable, control variable switching, valve protection function, max. switching current (resistive load) 16A , Number of outputs 3, Max. output current 16A, switching voltage 250 ... 250V, protection class (IP) IP20, min. depth of the device box 61.5mm, switching actuator 1-gang with three binary inputs for installation in a 60 mm flush-mounted box. Potential-free contacts can be connected to the three inputs. Optionally, an NTC temperature sensor can be connected to the third input. The inputs and the KNX are connected via a 6-wire, approx. 30 cm long connection cable. The connecting cable for the inputs can be extended up to a maximum of 10 m. KNX Secure compatible. KNX software functions: Switch actuator functions: Operation as normally closed or normally closed. Selection of the basic position in the event of bus voltage failure/recovery. Switch-on and/or switch-off delay. Timer function. Switch. Status feedback. Locking function or forced operation. Scene function (64). Feedback object can be inverted. Input functions: Free assignment of the switching, dimming, blind and value transmitter functions. Lock object. Behavior when bus voltage returns. Temperature, brightness, color temperature. Switching: two switching objects per input. Command on rising/falling edge (ON, OFF, TOGGLE, no reaction). Dimming: Single-surface and double-surface operation. Time between dimming and switching and dimming step values. Send telegram repetition and stop telegram. Blinds: Command on rising edge (none, UP, DOWN, TOGGLE), operating concept (Step - Move - Step or Move - Step). Time between short and long presses. Slat adjustment time. Value transmitter and light scene input: edge (button as make contact, button as break contact, switch) and value on edge. Value adjustment via long button press for value transmitter. Light scene extension with memory function. Logic module: link, converter, blocking element, comparator, limit value. Rated voltage: AC 230 V. Rated current: 16 A, ohmic load. Switching contact: NO contact, potential-free relay contact. Rated power: Incandescent lamps: AC 230 V, max. 2500 W. Halogen lamps: AC 230 V, max. 2500 W. HV LED lamps: AC 230 V, max. 400 W. Ohmic load: AC 230 V, 2500 W. Capacitive Load: AC 230 V, 16 A, max.?140 µF. LV halogen lamps: max. 1200 VA wound transformer, max. 1500 W electronic transformers. Inputs: 3.Temperature range: -5 °C to 45 °C.Dimensions: 48x50x28 (WxHxD). LV halogen lamps: max. 1200 VA wound transformer, max. 1500 W electronic transformers. Note: For installation in a double box or an electronics box (Kaiser). There must be a minimum distance of 4mm between the 230V connection and the connection for the KNX/inputs (SELV).
... more
Bus system KNX yes
Bus system KNX radio yes
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Other bus systems other
Radio bidirectional no
Mounting REG
Width in division units 4
With bus coupling yes
Bus module removable yes
Control variable steady no
Switching manipulated variable yes
Valve protection function yes
Manual gearshift no
Max. Switching current (resistive load) 16 A
Number of exits 3
Max. Output current 16 A
Switching voltage 250V
IP protection) IP20
Min. depth of the device socket 61.5 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "SpaceLogic KNX Fan Coil 0-10V controller - KNX Heating actuator for bus system MTN6730-0003"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.